Orifice Flow

Orifice Flow

开发者: Kaup Shenoy Associates

中国
APP ID 复制
479581349
分类
价格
R$19.90
内购
0个评分
工具(付费)
昨日下载量
最近更新
2025-04-29
最早发布
2011-11-15
版本统计
  • 113天23小时

    最新版本上线距今

  • 1

    近1年版本更新次数

  • 2011-11-15

    全球最早版本上线日期

版本记录
显示信息
日期
  • 全部
每页显示条数
  • 请选择
  • 版本: 2.2

    版本更新日期

    2025-04-29

    Orifice Flow

    Orifice Flow

    更新日志

    Updated for iOS 18 devices.

    视频/截图

    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图

    应用描述

    Measurement of fluid flow in pipes and conduits using orifice plates are very common in industrial applications. This app quickly computes the flow rates for liquid and gases based on standard parameters as per the model shown. Users can pick any fluid from a list of fifteen most common fluids used in industrial applications. Therefore, this app can be a very helpful tool for practicing engineers and designers in design and analysis of flows in different applications.

    A case study on CO2 flow rate is shown in the screen shot. The result is consistent with other methods used by the industry in computation and difference is less than 0.1%. Fluids that are not in the list, users can create a custom fluid with property data and compute the flow rate using the model provided in this app. Custom fluid data can be saved and reloaded every time when custom fluid is selected.

    Fluids:
    Air, Steam, Water, Nitrogen, Oxygen, Hydrogen, Helium, CO2, Methane, Ethane, Chlorine, Ammonia, Argon, Hydraulic oil, HFC(R410A), Custom (user's choice).

    Orifice Type:
    App gives four different standard orifice design with recommended discharge coefficients as shown in the following screen shot. It also provides the details of the model used in the computation of flow rates for liquid and gases. This model is valid even for nozzles, venturi-flow meters for which the discharge coefficient (Cd) is unity.

    Measuring Parameters:
    Fluid inlet temperature and pressure, orifice geometry, pressure differential using standard pressure taps (ISO 5167), are the standard parameters required in the computation. Based on the orifice geometry, recommended discharge coefficient Cd is used. However, users can edit this using manufacturer’s data for more accurate results. App notes provides brief description of different orifice parameters for quick reference.

    Unit of Measurement:
    Users can choose different unit of measurement for both flow as well as pressure drop under given unit standard (SI or USCS). This can be conveniently selected while choosing the fluid from the picker list.
    App notes provides additional guideline with a link for complete documentation on implementation and validation of math-models used with industry examples.
  • 版本: 2.1

    版本更新日期

    2024-04-25

    Orifice Flow

    Orifice Flow

    更新日志

    Updated for iOS 17 (iPhone15..)devices.

    应用描述

    暂无应用描述数据

  • 版本: 2.0

    版本更新日期

    2023-05-09

    Orifice Flow

    Orifice Flow

    更新日志

    Mandatory update for iOS 16.

    视频/截图

    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图

    应用描述

    Measurement of fluid flow in pipes and conduits using orifice plates are very common in industrial applications. This app quickly computes the flow rates for liquid and gases based on standard parameters as per the model shown. Users can pick any fluid from a list of fifteen most common fluids used in industrial applications. Therefore, this app can be a very helpful tool for practicing engineers and designers in design and analysis of flows in different applications.

    A case study on CO2 flow rate is shown in the screen shot. The result is consistent with other methods used by the industry in computation and difference is less than 0.1%. Fluids that are not in the list, users can create a custom fluid with property data and compute the flow rate using the model provided in this app. Custom fluid data can be saved and reloaded every time when custom fluid is selected.

    Fluids:
    Air, Steam, Water, Nitrogen, Oxygen, Hydrogen, Helium, CO2, Methane, Ethane, Chlorine, Ammonia, Argon, Hydraulic oil, HFC(R410A), Custom (user's choice).

    Orifice Type:
    App gives four different standard orifice design with recommended discharge coefficients as shown in the following screen shot. It also provides the details of the model used in the computation of flow rates for liquid and gases. This model is valid even for nozzles, venturi-flow meters for which the discharge coefficient (Cd) is unity.

    Measuring Parameters:
    Fluid inlet temperature and pressure, orifice geometry, pressure differential using standard pressure taps (ISO 5167), are the standard parameters required in the computation. Based on the orifice geometry, recommended discharge coefficient Cd is used. However, users can edit this using manufacturer’s data for more accurate results. App notes provides brief description of different orifice parameters for quick reference.

    Unit of Measurement:
    Users can choose different unit of measurement for both flow as well as pressure drop under given unit standard (SI or USCS). This can be conveniently selected while choosing the fluid from the picker list.
    App notes provides additional guideline with a link for complete documentation on implementation and validation of math-models used with industry examples.
  • 版本: 1.9

    版本更新日期

    2021-03-08

    Orifice Flow

    Orifice Flow

    更新日志

    Updated iOS14.4 and app notes with a link to additional documentation on implementation and validation of math-models with examples.

    视频/截图

    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图

    应用描述

    Measurement of fluid flow in pipes and conduits using orifice plates are very common in industrial applications. This app quickly computes the flow rates for liquid and gases based on standard parameters as per the model shown. Users can pick any fluid from a list of fifteen most common fluids used in industrial applications. Therefore, this app can be a very helpful tool for practicing engineers and designers in design and analysis of flows in different applications.

    A case study on CO2 flow rate is shown in the screen shot. The result is consistent with other methods used by the industry in computation and difference is less than 0.1%. Fluids that are not in the list, users can create a custom fluid with property data and compute the flow rate using the model provided in this app. Custom fluid data can be saved and reloaded every time when custom fluid is selected.

    Fluids:
    Air, Steam, Water, Nitrogen, Oxygen, Hydrogen, Helium, CO2, Methane, Ethane, Chlorine, Ammonia, Argon, Hydraulic oil, HFC(R410A), Custom (user's choice).

    Orifice Type:
    App gives four different standard orifice design with recommended discharge coefficients as shown in the following screen shot. It also provides the details of the model used in the computation of flow rates for liquid and gases. This model is valid even for nozzles, venturi-flow meters for which the discharge coefficient (Cd) is unity.

    Measuring Parameters:
    Fluid inlet temperature and pressure, orifice geometry, pressure differential using standard pressure taps (ISO 5167), are the standard parameters required in the computation. Based on the orifice geometry, recommended discharge coefficient Cd is used. However, users can edit this using manufacturer’s data for more accurate results. App notes provides brief description of different orifice parameters for quick reference.

    Unit of Measurement:
    Users can choose different unit of measurement for both flow as well as pressure drop under given unit standard (SI or USCS). This can be conveniently selected while choosing the fluid from the picker list.
    App notes provides additional guideline with a link for complete documentation on implementation and validation of math-models used with industry examples.
  • 版本: 1.8

    版本更新日期

    2020-10-25

    Orifice Flow

    Orifice Flow

    更新日志

    Updated for iOS 14 devices.

    视频/截图

    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图

    应用描述

    Measurement of fluid flow in pipes and conduits using orifice plates are very common in industrial applications. This app quickly computes the flow rates for liquid and gases based on standard parameters as per the model shown. Users can pick any fluid from a list of fifteen most common fluids used in industrial applications. Therefore, this app can be a very helpful tool for practicing engineers and designers in design and analysis of flows in different applications.

    A case study on CO2 flow rate is shown in the screen shot. The result is consistent with other methods used by the industry in computation and difference is less than 0.1%. Fluids that are not in the list, users can create a custom fluid with property data and compute the flow rate using the model provided in this app. Custom fluid data can be saved and reloaded every time when custom fluid is selected.

    Fluids:
    Air, Steam, Water, Nitrogen, Oxygen, Hydrogen, Helium, CO2, Methane, Ethane, Chlorine, Ammonia, Argon, Hydraulic oil, HFC(R410A), Custom (user's choice).

    Orifice Type:
    App gives four different standard orifice design with recommended discharge coefficients as shown in the following screen shot. It also provides the details of the model used in the computation of flow rates for liquid and gases. This model is valid even for nozzles, venturi-flow meters for which the discharge coefficient (Cd) is unity.

    Measuring Parameters:
    Fluid inlet temperature and pressure, orifice geometry, pressure differential using standard pressure taps (ISO 5167), are the standard parameters required in the computation. Based on the orifice geometry, recommended discharge coefficient Cd is used. However, users can edit this using manufacturer’s data for more accurate results. App notes provides brief description of different orifice parameters for quick reference.

    Unit of Measurement:
    Users can choose different unit of measurement for both flow as well as pressure drop under given unit standard (SI or USCS). This can be conveniently selected while choosing the fluid from the picker list.
  • 版本: 1.7

    版本更新日期

    2020-08-04

    Orifice Flow

    Orifice Flow

    更新日志

    Updated with iOS 13.0 and macOS Catalina.

    视频/截图

    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图

    应用描述

    Measurement of fluid flow in pipes and conduits using orifice plates are very common in industrial applications. This app quickly computes the flow rates for liquid and gases based on standard parameters as per the model shown. Users can pick any fluid from a list of fifteen most common fluids used in industrial applications. Therefore, this app can be a very helpful tool for practicing engineers and designers in design and analysis of flows in different applications.

    A case study on CO2 flow rate is shown in the screen shot. The result is consistent with other methods used by the industry in computation and difference is less than 0.1%. Fluids that are not in the list, users can create a custom fluid with property data and compute the flow rate using the model provided in this app. Custom fluid data can be saved and reloaded every time when custom fluid is selected.

    Fluids:
    Air, Steam, Water, Nitrogen, Oxygen, Hydrogen, Helium, CO2, Methane, Ethane, Chlorine, Ammonia, Argon, Hydraulic oil, HFC(R410A), Custom (user's choice).

    Orifice Type:
    App gives four different standard orifice design with recommended discharge coefficients as shown in the following screen shot. It also provides the details of the model used in the computation of flow rates for liquid and gases. This model is valid even for nozzles, venturi-flow meters for which the discharge coefficient (Cd) is unity.

    Measuring Parameters:
    Fluid inlet temperature and pressure, orifice geometry, pressure differential using standard pressure taps (ISO 5167), are the standard parameters required in the computation. Based on the orifice geometry, recommended discharge coefficient Cd is used. However, users can edit this using manufacturer’s data for more accurate results. App notes provides brief description of different orifice parameters for quick reference.

    Unit of Measurement:
    Users can choose different unit of measurement for both flow as well as pressure drop under given unit standard (SI or USCS). This can be conveniently selected while choosing the fluid from the picker list.
  • 版本: 1.6

    版本更新日期

    2019-06-18

    Orifice Flow

    Orifice Flow

    更新日志

    Bug fixes from last update on HFC refrigerant inclusion.

    视频/截图

    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图

    应用描述

    Measurement of fluid flow in pipes and conduits using orifice plates are very common in industrial applications. This app quickly computes the flow rates for liquid and gases based on standard parameters as per the model shown. Users can pick any fluid from a list of fifteen most common fluids used in industrial applications. Therefore, this app can be a very helpful tool for practicing engineers and designers in design and analysis of flows in different applications.

    A case study on CO2 flow rate is shown in the screen shot. The result is consistent with other methods used by the industry in computation and difference is less than 0.1%. Fluids that are not in the list, users can create a custom fluid with property data and compute the flow rate using the model provided in this app. Custom fluid data can be saved and reloaded every time when custom fluid is selected.

    Fluids:
    Air, Steam, Water, Nitrogen, Oxygen, Hydrogen, Helium, CO2, Methane, Ethane, Chlorine, Ammonia, Argon, Hydraulic oil, HFC(R410A), Custom (user's choice).

    Orifice Type:
    App gives four different standard orifice design with recommended discharge coefficients as shown in the following screen shot. It also provides the details of the model used in the computation of flow rates for liquid and gases. This model is valid even for nozzles, venturi-flow meters for which the discharge coefficient (Cd) is unity.

    Measuring Parameters:
    Fluid inlet temperature and pressure, orifice geometry, pressure differential using standard pressure taps (ISO 5167), are the standard parameters required in the computation. Based on the orifice geometry, recommended discharge coefficient Cd is used. However, users can edit this using manufacturer’s data for more accurate results. App notes provides brief description of different orifice parameters for quick reference.

    Unit of Measurement:
    Users can choose different unit of measurement for both flow as well as pressure drop under given unit standard (SI or USCS). This can be conveniently selected while choosing the fluid from the picker list.
  • 版本: 1.5

    版本更新日期

    2019-06-12

    Orifice Flow

    Orifice Flow

    更新日志

    Mandatory update for iOS 12 devices. Replaced refrigerant Freon R12 with HFC R410A in the fluid list.

    视频/截图

    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图
    Orifice Flow App 截图

    应用描述

    Measurement of fluid flow in pipes and conduits using orifice plates are very common in industrial applications. This app quickly computes the flow rates for liquid and gases based on standard parameters as per the model shown. Users can pick any fluid from a list of fifteen most common fluids used in industrial applications. Therefore, this app can be a very helpful tool for practicing engineers and designers in design and analysis of flows in different applications.

    A case study on CO2 flow rate is shown in the screen shot. The result is consistent with other methods used by the industry in computation and difference is less than 0.1%. Fluids that are not in the list, users can create a custom fluid with property data and compute the flow rate using the model provided in this app. Custom fluid data can be saved and reloaded every time when custom fluid is selected.

    Fluids:
    Air, Steam, Water, Nitrogen, Oxygen, Hydrogen, Helium, CO2, Methane, Ethane, Chlorine, Ammonia, Argon, Hydraulic oil, HFC(R410A), Custom (user's choice).

    Orifice Type:
    App gives four different standard orifice design with recommended discharge coefficients as shown in the following screen shot. It also provides the details of the model used in the computation of flow rates for liquid and gases. This model is valid even for nozzles, venturi-flow meters for which the discharge coefficient (Cd) is unity.

    Measuring Parameters:
    Fluid inlet temperature and pressure, orifice geometry, pressure differential using standard pressure taps (ISO 5167), are the standard parameters required in the computation. Based on the orifice geometry, recommended discharge coefficient Cd is used. However, users can edit this using manufacturer’s data for more accurate results. App notes provides brief description of different orifice parameters for quick reference.

    Unit of Measurement:
    Users can choose different unit of measurement for both flow as well as pressure drop under given unit standard (SI or USCS). This can be conveniently selected while choosing the fluid from the picker list.
  • 版本: 1.4

    版本更新日期

    2015-05-06

    Orifice Flow

    Orifice Flow

    更新日志

    iOS 8 compliant. Updated for iPhone 6 and iPhone 6+ with bug fixes. Runs on iOS devices with iOS 6.1 and above.

    应用描述

    暂无应用描述数据

  • 版本: 1.3

    版本更新日期

    2013-09-08

    Orifice Flow

    Orifice Flow

    更新日志

    This update is mainly for 4 inch display (iPhone5) where a few unconstrained UI objects got displaced in 4-in screen layout as they were originally placed for 320x480px devices.

    应用描述

    暂无应用描述数据