3D ECG Leads

3D ECG Leads

ECG Leads Pocket Guide

开发者: XR Anatomy LTD

中国
APP ID 复制
1447415829
分类
价格
USD4.99
内购
0个评分
医疗(付费)
昨日下载量
最近更新
2020-07-26
最早发布
2019-03-14
版本统计
  • 1857天15小时

    最新版本上线距今

  • 0

    近1年版本更新次数

  • 2019-03-14

    全球最早版本上线日期

版本记录
显示信息
日期
  • 全部
每页显示条数
  • 请选择
  • 版本: 2.0

    版本更新日期

    2020-07-26

    3D ECG Leads

    3D ECG Leads

    ECG Leads Pocket Guide

    更新日志

    Ipad Version
    Fixed minor bugs
    Removed Analytics

    视频/截图

    3D ECG Leads App 视频
    3D ECG Leads App 截图
    3D ECG Leads App 截图
    3D ECG Leads App 截图
    3D ECG Leads App 截图
    3D ECG Leads App 截图
    3D ECG Leads App 截图
    3D ECG Leads App 截图
    3D ECG Leads App 截图
    3D ECG Leads App 截图
    3D ECG Leads App 截图

    应用描述

    Why 3D ECG Leads ?

    AN ECG LEAD PLACEMENT GUIDE

    Misplacement of the ECG Leads may lead to wrong diagnoses and further unnecessary investigations or treatments (Jowett et al., 2005; Toosi and Sochanski, 2008; Harrigan, Chan and Brady, 2012; Ilg and Lehmann, 2012; Lynch, 2014). In their study (Medani et al., 2018) showed that in only 34% of cases, the ECG Chest Leads were placed correctly.

    All medical personnel who are operating a 12 Lead ECG machine should have the appropriate training for ECG lead placement (Kligfield et al., 2007; Crawford and Doherty, 2010). The purpose of 3D ECG Leads is not aimed at replacing high-quality training but instead, to act as an aid and to show you in a simple 3D interactive way the Standard Lead Placement Technique.

    AN ECG LEADS VISUALISATION TOOL

    In a standard 12 Lead ECG Tracing, not all of the ECG Leads are organized in anatomical order. One recent study (Lindow et al., 2019) highlights the fact that displaying all the 12 ECG Leads in an anatomical sequence has a positive impact in diagnosing Acute Myocardial Infarction. 3D ECG Leads serves as a 3D interactive tool for the anatomical visualization of the ECG Leads.

    WHY ONLY 10 LEADS. HOW AN ECG LEAD IS GENERATED.

    With 3D ECG Leads you can visualize how the ECG Machine reads the heart's electrical activity, and how 3 Electrodes are generating 6 Leads.

    References

    Crawford, J. and Doherty, L. (2010) “Ten steps to recording a standard 12-lead ECG,” Practice Nursing, 21(12). doi: 10.12968/pnur.2010.21.12.622.

    Harrigan, R. A., Chan, T. C. and Brady, W. J. (2012) “Electrocardiographic electrode misplacement, misconnection, and artifact,” Journal of Emergency Medicine. Elsevier Ltd, 43(6). doi: 10.1016/j.jemermed.2012.02.024.

    Ilg, K. J. and Lehmann, M. H. (2012) “Importance of recognizing pseudo-septal infarction due to electrocardiographic lead misplacement,” American Journal of Medicine. Elsevier Inc., 125(1). doi: 10.1016/j.amjmed.2011.04.023.

    Jowett, N. I. et al. (2005) “Modified electrode placement must be recorded when performing 12-lead electrocardiograms,” Postgraduate Medical Journal, 81(952). doi: 10.1136/pgmj.2004.021204.

    Kligfield, P. et al. (2007) “Recommendations for the Standardization and Interpretation of the Electrocardiogram: Part I: The Electrocardiogram and Its Technology A Scientific Statement From the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clin,” Journal of the American College of Cardiology. Elsevier, 49(10). doi: 10.1016/J.JACC.2007.01.024.

    Lindow, T. et al. (2019) “Why complicate an important task? An orderly display of the limb leads in the 12-lead electrocardiogram and its implications for recognition of acute coronary syndrome,” BMC Cardiovascular Disorders. BMC Cardiovascular Disorders, 19(1). doi: 10.1186/s12872-018-0979-x.

    Lynch, R. (2014) “ECG lead misplacement: A brief review of limb lead misplacement,” African Journal of Emergency Medicine. African Federation for Emergency Medicine, 4(3). doi: 10.1016/j.afjem.2014.05.006.

    Medani, S. A. et al. (2018) “Accuracy in precordial ECG lead placement: Improving performance through a peer-led educational intervention,” Journal of Electrocardiology. Elsevier Inc., 51(1). doi: 10.1016/j.jelectrocard.2017.04.018.

    Toosi, M. S. and Sochanski, M. T. (2008) “False ST elevation in a modified 12-lead surface electrocardiogram,” Journal of Electrocardiology, 41(3). doi: 10.1016/j.jelectrocard.2007.11.004.
  • 版本: 1.1

    版本更新日期

    2019-05-30

    3D ECG Leads

    3D ECG Leads

    ECG Leads Pocket Guide

    更新日志

    Improved User Interface
    Redesigned Info Menu
    Improved Textures
    Bug fixes

    视频/截图

    3D ECG Leads App 视频
    3D ECG Leads App 截图
    3D ECG Leads App 截图
    3D ECG Leads App 截图
    3D ECG Leads App 截图
    3D ECG Leads App 截图
    3D ECG Leads App 截图
    3D ECG Leads App 截图
    3D ECG Leads App 截图
    3D ECG Leads App 截图
    3D ECG Leads App 截图

    应用描述

    Why 3D ECG Leads ?

    AN ECG LEAD PLACEMENT GUIDE

    Misplacement of the ECG Leads may lead to wrong diagnoses and further unnecessary investigations or treatments (Jowett et al., 2005; Toosi and Sochanski, 2008; Harrigan, Chan and Brady, 2012; Ilg and Lehmann, 2012; Lynch, 2014). In their study (Medani et al., 2018) showed that in only 34% of cases, the ECG Chest Leads were placed correctly.

    All medical personnel who are operating a 12 Lead ECG machine should have the appropriate training for ECG lead placement (Kligfield et al., 2007; Crawford and Doherty, 2010). The purpose of 3D ECG Leads is not aimed at replacing high-quality training but instead, to act as an aid and to show you in a simple 3D interactive way the Standard Lead Placement Technique.

    AN ECG LEADS VISUALISATION TOOL

    In a standard 12 Lead ECG Tracing, not all of the ECG Leads are organized in anatomical order. One recent study (Lindow et al., 2019) highlights the fact that displaying all the 12 ECG Leads in an anatomical sequence has a positive impact in diagnosing Acute Myocardial Infarction. 3D ECG Leads serves as a 3D interactive tool for the anatomical visualization of the ECG Leads.

    WHY ONLY 10 LEADS. HOW AN ECG LEAD IS GENERATED.

    With 3D ECG Leads you can visualize how the ECG Machine reads the heart's electrical activity, and how 3 Electrodes are generating 6 Leads.

    References

    Crawford, J. and Doherty, L. (2010) “Ten steps to recording a standard 12-lead ECG,” Practice Nursing, 21(12). doi: 10.12968/pnur.2010.21.12.622.

    Harrigan, R. A., Chan, T. C. and Brady, W. J. (2012) “Electrocardiographic electrode misplacement, misconnection, and artifact,” Journal of Emergency Medicine. Elsevier Ltd, 43(6). doi: 10.1016/j.jemermed.2012.02.024.

    Ilg, K. J. and Lehmann, M. H. (2012) “Importance of recognizing pseudo-septal infarction due to electrocardiographic lead misplacement,” American Journal of Medicine. Elsevier Inc., 125(1). doi: 10.1016/j.amjmed.2011.04.023.

    Jowett, N. I. et al. (2005) “Modified electrode placement must be recorded when performing 12-lead electrocardiograms,” Postgraduate Medical Journal, 81(952). doi: 10.1136/pgmj.2004.021204.

    Kligfield, P. et al. (2007) “Recommendations for the Standardization and Interpretation of the Electrocardiogram: Part I: The Electrocardiogram and Its Technology A Scientific Statement From the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clin,” Journal of the American College of Cardiology. Elsevier, 49(10). doi: 10.1016/J.JACC.2007.01.024.

    Lindow, T. et al. (2019) “Why complicate an important task? An orderly display of the limb leads in the 12-lead electrocardiogram and its implications for recognition of acute coronary syndrome,” BMC Cardiovascular Disorders. BMC Cardiovascular Disorders, 19(1). doi: 10.1186/s12872-018-0979-x.

    Lynch, R. (2014) “ECG lead misplacement: A brief review of limb lead misplacement,” African Journal of Emergency Medicine. African Federation for Emergency Medicine, 4(3). doi: 10.1016/j.afjem.2014.05.006.

    Medani, S. A. et al. (2018) “Accuracy in precordial ECG lead placement: Improving performance through a peer-led educational intervention,” Journal of Electrocardiology. Elsevier Inc., 51(1). doi: 10.1016/j.jelectrocard.2017.04.018.

    Toosi, M. S. and Sochanski, M. T. (2008) “False ST elevation in a modified 12-lead surface electrocardiogram,” Journal of Electrocardiology, 41(3). doi: 10.1016/j.jelectrocard.2007.11.004.
  • 版本: 1.0

    版本更新日期

    2019-03-14

    3D ECG Leads

    3D ECG Leads

    ECG Leads Pocket Guide

    更新日志

    暂无更新日志数据

    应用描述

    暂无应用描述数据